FDA regulatory consultant for medical device companies. Provides 510(k)/PMA/De Novo pathway guidance, QSR (21 CFR 820) compliance, HIPAA assessments, and device cybersecurity. Use when user mentions FDA submission, 510(k), PMA, De Novo, QSR, premarket, predicate device, substantial equivalence, HIPAA medical device, or FDA cybersecurity.

Safety Notice

This listing is from the official public ClawHub registry. Review SKILL.md and referenced scripts before running.

Copy this and send it to your AI assistant to learn

Install skill "fda-consultant-specialist" with this command: npx skills add alirezarezvani/fda-consultant-specialist

FDA Consultant Specialist

FDA regulatory consulting for medical device manufacturers covering submission pathways, Quality System Regulation (QSR), HIPAA compliance, and device cybersecurity requirements.

Table of Contents


FDA Pathway Selection

Determine the appropriate FDA regulatory pathway based on device classification and predicate availability.

Decision Framework

Predicate device exists?
├── YES → Substantially equivalent?
│   ├── YES → 510(k) Pathway
│   │   ├── No design changes → Abbreviated 510(k)
│   │   ├── Manufacturing only → Special 510(k)
│   │   └── Design/performance → Traditional 510(k)
│   └── NO → PMA or De Novo
└── NO → Novel device?
    ├── Low-to-moderate risk → De Novo
    └── High risk (Class III) → PMA

Pathway Comparison

PathwayWhen to UseTimelineCost
510(k) TraditionalPredicate exists, design changes90 days$21,760
510(k) SpecialManufacturing changes only30 days$21,760
510(k) AbbreviatedGuidance/standard conformance30 days$21,760
De NovoNovel, low-moderate risk150 days$134,676
PMAClass III, no predicate180+ days$425,000+

Pre-Submission Strategy

  1. Identify product code and classification
  2. Search 510(k) database for predicates
  3. Assess substantial equivalence feasibility
  4. Prepare Q-Sub questions for FDA
  5. Schedule Pre-Sub meeting if needed

Reference: See fda_submission_guide.md for pathway decision matrices and submission requirements.


510(k) Submission Process

Workflow

Phase 1: Planning
├── Step 1: Identify predicate device(s)
├── Step 2: Compare intended use and technology
├── Step 3: Determine testing requirements
└── Checkpoint: SE argument feasible?

Phase 2: Preparation
├── Step 4: Complete performance testing
├── Step 5: Prepare device description
├── Step 6: Document SE comparison
├── Step 7: Finalize labeling
└── Checkpoint: All required sections complete?

Phase 3: Submission
├── Step 8: Assemble submission package
├── Step 9: Submit via eSTAR
├── Step 10: Track acknowledgment
└── Checkpoint: Submission accepted?

Phase 4: Review
├── Step 11: Monitor review status
├── Step 12: Respond to AI requests
├── Step 13: Receive decision
└── Verification: SE letter received?

Required Sections (21 CFR 807.87)

SectionContent
Cover LetterSubmission type, device ID, contact info
Form 3514CDRH premarket review cover sheet
Device DescriptionPhysical description, principles of operation
Indications for UseForm 3881, patient population, use environment
SE ComparisonSide-by-side comparison with predicate
Performance TestingBench, biocompatibility, electrical safety
Software DocumentationLevel of concern, hazard analysis (IEC 62304)
LabelingIFU, package labels, warnings
510(k) SummaryPublic summary of submission

Common RTA Issues

IssuePrevention
Missing user feeVerify payment before submission
Incomplete Form 3514Review all fields, ensure signature
No predicate identifiedConfirm K-number in FDA database
Inadequate SE comparisonAddress all technological characteristics

QSR Compliance

Quality System Regulation (21 CFR Part 820) requirements for medical device manufacturers.

Key Subsystems

SectionTitleFocus
820.20Management ResponsibilityQuality policy, org structure, management review
820.30Design ControlsInput, output, review, verification, validation
820.40Document ControlsApproval, distribution, change control
820.50Purchasing ControlsSupplier qualification, purchasing data
820.70Production ControlsProcess validation, environmental controls
820.100CAPARoot cause analysis, corrective actions
820.181Device Master RecordSpecifications, procedures, acceptance criteria

Design Controls Workflow (820.30)

Step 1: Design Input
└── Capture user needs, intended use, regulatory requirements
    Verification: Inputs reviewed and approved?

Step 2: Design Output
└── Create specifications, drawings, software architecture
    Verification: Outputs traceable to inputs?

Step 3: Design Review
└── Conduct reviews at each phase milestone
    Verification: Review records with signatures?

Step 4: Design Verification
└── Perform testing against specifications
    Verification: All tests pass acceptance criteria?

Step 5: Design Validation
└── Confirm device meets user needs in actual use conditions
    Verification: Validation report approved?

Step 6: Design Transfer
└── Release to production with DMR complete
    Verification: Transfer checklist complete?

CAPA Process (820.100)

  1. Identify: Document nonconformity or potential problem
  2. Investigate: Perform root cause analysis (5 Whys, Fishbone)
  3. Plan: Define corrective/preventive actions
  4. Implement: Execute actions, update documentation
  5. Verify: Confirm implementation complete
  6. Effectiveness: Monitor for recurrence (30-90 days)
  7. Close: Management approval and closure

Reference: See qsr_compliance_requirements.md for detailed QSR implementation guidance.


HIPAA for Medical Devices

HIPAA requirements for devices that create, store, transmit, or access Protected Health Information (PHI).

Applicability

Device TypeHIPAA Applies
Standalone diagnostic (no data transmission)No
Connected device transmitting patient dataYes
Device with EHR integrationYes
SaMD storing patient informationYes
Wellness app (no diagnosis)Only if stores PHI

Required Safeguards

Administrative (§164.308)
├── Security officer designation
├── Risk analysis and management
├── Workforce training
├── Incident response procedures
└── Business associate agreements

Physical (§164.310)
├── Facility access controls
├── Workstation security
└── Device disposal procedures

Technical (§164.312)
├── Access control (unique IDs, auto-logoff)
├── Audit controls (logging)
├── Integrity controls (checksums, hashes)
├── Authentication (MFA recommended)
└── Transmission security (TLS 1.2+)

Risk Assessment Steps

  1. Inventory all systems handling ePHI
  2. Document data flows (collection, storage, transmission)
  3. Identify threats and vulnerabilities
  4. Assess likelihood and impact
  5. Determine risk levels
  6. Implement controls
  7. Document residual risk

Reference: See hipaa_compliance_framework.md for implementation checklists and BAA templates.


Device Cybersecurity

FDA cybersecurity requirements for connected medical devices.

Premarket Requirements

ElementDescription
Threat ModelSTRIDE analysis, attack trees, trust boundaries
Security ControlsAuthentication, encryption, access control
SBOMSoftware Bill of Materials (CycloneDX or SPDX)
Security TestingPenetration testing, vulnerability scanning
Vulnerability PlanDisclosure process, patch management

Device Tier Classification

Tier 1 (Higher Risk):

  • Connects to network/internet
  • Cybersecurity incident could cause patient harm

Tier 2 (Standard Risk):

  • All other connected devices

Postmarket Obligations

  1. Monitor NVD and ICS-CERT for vulnerabilities
  2. Assess applicability to device components
  3. Develop and test patches
  4. Communicate with customers
  5. Report to FDA per guidance

Coordinated Vulnerability Disclosure

Researcher Report
    ↓
Acknowledgment (48 hours)
    ↓
Initial Assessment (5 days)
    ↓
Fix Development
    ↓
Coordinated Public Disclosure

Reference: See device_cybersecurity_guidance.md for SBOM format examples and threat modeling templates.


Resources

scripts/

ScriptPurpose
fda_submission_tracker.pyTrack 510(k)/PMA/De Novo submission milestones and timelines
qsr_compliance_checker.pyAssess 21 CFR 820 compliance against project documentation
hipaa_risk_assessment.pyEvaluate HIPAA safeguards in medical device software

references/

FileContent
fda_submission_guide.md510(k), De Novo, PMA submission requirements and checklists
qsr_compliance_requirements.md21 CFR 820 implementation guide with templates
hipaa_compliance_framework.mdHIPAA Security Rule safeguards and BAA requirements
device_cybersecurity_guidance.mdFDA cybersecurity requirements, SBOM, threat modeling
fda_capa_requirements.mdCAPA process, root cause analysis, effectiveness verification

Usage Examples

# Track FDA submission status
python scripts/fda_submission_tracker.py /path/to/project --type 510k

# Assess QSR compliance
python scripts/qsr_compliance_checker.py /path/to/project --section 820.30

# Run HIPAA risk assessment
python scripts/hipaa_risk_assessment.py /path/to/project --category technical

Source Transparency

This detail page is rendered from real SKILL.md content. Trust labels are metadata-based hints, not a safety guarantee.

Related Skills

Related by shared tags or category signals.

Coding

CP2K Cross-Code Input Studio

Generate, refine, explain, and cross-convert CP2K-centered input drafts for computational chemistry and materials workflows. Use when a user wants a CP2K .in...

Registry SourceRecently Updated
Coding

PDF to markdown converter

Convert PDF and image documents to clean Markdown via the PDF2Markdown CLI. Use when the user wants to extract text from PDFs, convert PDFs to markdown, pars...

Registry SourceRecently Updated
Coding

VMware Monitor

VMware vCenter/ESXi read-only monitoring skill. Code-level enforced safety — no destructive operations exist in this codebase. Query inventory, check health/...

Registry SourceRecently Updated
0318
zw008